ISO 13849-1 : Standard of Industrial Safety, Performance Level d (PL d)
PL d Advanced Training: Control System Safety Guide
P
PL d Education
Module 1: Definition
Module 2: Requirements
Module 3: Circuit
Module 4: Verification
ISO 13849-1 Advanced Course
Standard of Industrial Safety,
Performance Level d (PL d)
Why do robots and automation systems require PL d?
Learn the design know-how to reduce the probability of dangerous failure to 1 in 10 million.
Module 1. Definition and Meaning of PL d
How safe must it be to be PL d?
Probability of Dangerous Failure per Hour (PFHd)
The PL grade is not just saying “it’s safe”.
It quantifies the “probability of a dangerous failure occurring during 1 hour of operation”.
PL
PFHd (1/h)
Reliability Level
PL c
≥ 10-6 ~ < 3 × 10-6
1 in a Million
PL d
≥ 10-7 ~ < 10-6
1 in 10 Million
PL e
≥ 10-8 ~ < 10-7
1 in 100 Million
Why is PL d for Robots?
S2
Serious Injury (Severity)
Possibility of fracture, amputation, or death upon collision.
F2
Frequent Exposure (Frequency)
Operators frequently approach the robot in automation lines.
P1
Possibility of Avoidance
Can be avoided under specific conditions (e.g., slow speed).
Risk Assessment Result ⇒ Minimum PL d Required
Module 2. Recipe to Achieve PL d
The standard design combination to achieve PL d
The Golden Formula for PL d
Most common “Category 3” based configuration
1
Category 3
Architectural Requirements
Redundancy
No loss of safety function
even with a single fault
2
MTTFd
Component Reliability
Medium ~ High
Use certified components
with low failure rates (Check B10d)
3
DCavg
Diagnostic Coverage
Low ~ Medium
Cross-check (Feedback)
of I/O status
Note: While theoretically Category 2 (Single channel + Test) can achieve PL d, Category 3 (Redundancy) is the industrial standard for robot systems due to control complexity and test cycle limitations.
Module 3. Practical Circuit Design (Category 3)
Example of perfect redundancy from input to output
INPUT
E-Stop Button
NC 1
NC 2
★ 2 Contacts (Redundancy)
LOGIC
Safety PLC / Relay
Channel A Processing
Channel B Processing
Cross Monitoring
OUTPUT
Power Cut-off (MC)
MC 1
MC 2
★ Series Connection
EDM (External Device Monitoring) Feedback Loop
Common Mistakes (Failure Causes)
-
Single Contact: Connecting E-Stop with only 1 contact (Cat 1 or lower).
-
Standard PLC: Handling Safety Functions with standard PLC logic (No diagnostics).
-
Fault Masking: Simple series connection of multiple E-Stop buttons prevents fault detection.
Success Points (Check Point)
-
EDM Mandatory: Feedback of the output MC’s auxiliary contact (NC) to the safety controller.
-
CCF Consideration: Separate cabling or shielding to prevent common cause failures.
Module 4. Verification & Software
Manual PL calculation is prone to errors. Verification software is used in the industrial field.
P
PAScal
Safety calculation software by Pilz
S
SISTEMA
Free standard tool by IFA (Widely used)
Education Material
Based on EN ISO 13849-1:2015
Advanced Safety Training
© Safety Guide. Specialized for PL d.